Akvaterm Solar Accumulator Tank

The AKVAir Solar is available from 300-2000 litres and is 3 bar pressure rated. The tank has 3 coils, one for solar input and two for domestic hot water (DHW).

The coils are permanently fitted and not removable as in the AKVA, AKVASAN and AKVANTTI tanks.

The tank is divided by a baffle plate with approximately 60% below and 40% above the baffle. The solar coil and the pre-heat DHW coils are positioned vertically in the lower part of the tank.

The solar coil is connected for downwards flow and the domestic water for upwards flow.

The secondary DHW coil is located above the baffle plate, for connection in series from the lower coil. A thermostatic mixing valve can be installed between the lower and upper DHW coils if desired to reduce flow through the top coil. A thermostatic mixing valve is required in all cases after the top DHW coil.

Automatic boilers, whether gas, oil, wood chip or wood pellet, are connected across the top and mid point of the tank. Batch fed boilers and stoves should be connected top and bottom to provide the full buffer volume of the tank.

Radiator circuits are connected flow from the top of the tank and return to mid point. Underfloor heating circuits can be connected flow from the mid point, return to the bottom. Heating flow temperature can be controlled using a 3 way blending valve and regulator such as the Thermomatic K.

Systems incorporating both radiator and underfloor heating can be connected with flow from both the top and the mid point using a 4 way bi-valent blending valve controlled by a Thermomatic K or similar. This arrangement makes use of heat energy from the mid point of the tank when available.

Akvaterm’s Solar and Solar Plus range of tanks are designed to make solar energy available to both heating and DHW. If the top of the tank is not connected to an automatic boiler capable of meeting the heating demand consideration must be given to the control of the heating to prevent depletion of the heat reserve for DHW.

 

MODEL
Capacity (l)
Pressure Rating
Diameter mm
Height mm
Coils*
Insulation
AKVA Solar 300
300
3 Bar
650
2050
1x Solar 2x DHW
70mm seamless urethane
AKVA Solar 500
500
3 Bar
800
2050
1x Solar 2x DHW
100mm seamless urethane
AKVA Solar 750
750
3 Bar
950
2100
1x Solar 2x DHW
100mm seamless urethane
AKVA Solar 1000
1000
3 Bar
1050
2100
1x Solar 2x DHW
100mm seamless urethane
AKVA Solar 1500
1500
3 Bar
1250
2150
1x Solar 2x DHW
100mm seamless urethane
AKVA Solar 2000
2000
3 Bar
1400
2200
1x Solar 2x DHW
100mm seamless urethane
 


*Coils
Solar = 18mm finned copper (12.2 metres)
DHW = Domestic hot water preheat coil, 22mm finned copper (9.4 metres)


SIZE PURPOSE
1.
1 1/4”
From boiler / to central heating
2.
1 1/4”
From central heating / to boiler
4.
2 “
Immersion heater
5.
1 “
Drain coupling or to boiler
6.
1 “ Bleed
7.
3/4” Thermostat or thermometer unit
T.
Thermostat pocket
COIL CONNECTIONS
8.
Ø18 Output solar
9.
Ø18 Input solar
10.
Ø20 Input (mains), (DHW preheat)
11.
Ø20 Output, DHW preheat
12.
Ø20 Input, DHW
13.
Ø20 Output, DHW


   
    site map